UPS for Home/Small Office Use

In India, power distribution and availability of uninterrupted power supply is still an issue. We  offers a range of inverters, home UPS and inverter batteries to choose from. When most companies talk about solutions for power-cuts, we go a step further in bringing quality back-up power supply for unhindered performance during power-cuts. So you can live your life uninterrupted. 

Our home UPS ranges starts from 0.5Kva to 10Kva.

These are high efficient,high frequency and Transformer less design.

Warranty:- 2 Years

Brand:- MRO-Tek

Technical Specificaion

1. AC Input Voltage 230V + 15%-5V
2. Mains Mode
   a. Fast changeover Mode(FC)
      i. Mains Low Cut 180V+/-5V
      ii. Mains High Cut 260V+/-5V
   b. Slow changeover Mode(FC)
      i. Mains Low Cut 100V+/-5V
      ii. Mains High Cut 280V+/-5V
3. Battery Voltage 12V
4. AC O/P Voltage at No Load 220 +/- 7V
5. Output frequency 50HZ + 0.1 Hz
6. Battery Charging Boost mode & Trickle mode with required current limit
7. Battery Lower Voltage limit 10.1V for single Battery
8. Battery Maximum Charging Current 10A+/-1.5A
9. Recommended Battery Capacity 80-200AH/12V

Application Chart – UPS

Appliance Rating
Home UPS NS 512 500 VA /400 Watt
Home UPS  NS 812 800 VA /480 Watt
Home UPS  NS 1012 1000 VA /600 Watt
Home UPS NS 1424 1400 VA /840 Watt
Home UPS NS 2048 2000 VA /1600 Watt
Home UPS NS 3048 3000 VA /2400 Watt

Applications

  • Power back-up for your home/office
  • Domestic computer and its peripherals
  • Emergency power systems
  • Photography
  • Small water pumps and all motor based low-power applications
  • TV, Fans, Tube lights
  • Professional applications where waveform is critical

Key Features

  • DSP-based control guarantees high reliability
  • Pure Sine wave output
  • Compact and lightweight
  • Simple and easy installation
  • High efficiency and longer back-up time
  • Intelligent charging ensuring more battery life
  • Normal and Computer mode operation of the UPS
  • Noiseless operation of fans, lamps and appliances
  • No load sleep: for loads  less than 10W, the inverter goes to sleep automatically to save power
  • Phase reversal protection
  • Overload protection and auto recovery
  • Short-circuit protection
  • LCD / LED display for UPS status monitoring

 Environment

  • Humidity                          :               0-90% RH
  • Operating temperature      :               0-50 degree C

Protection

  • Lightning, battery over voltage, battery under-voltage, output short circuit, overload, mains over voltage, mains lower voltage, over temperature.